Fire System Audit
Every system needs a periodic review
A very obvious question comes in mind of every prospect.
What can go wrong if Fire System is not designed properly.
Few of our past prestigious projects.
Fire System Design Consultancy or Adequecy Audit
What is a Fire System Audit?
Fire Safety Audit:
A fire safety audit is a tool used to assess the fire safety standards of an organization or building. A comprehensive fire safety audit assesses the inherent fire risks associated with daily operations and recommends measures to mitigate potential fire hazards.
We conduct fire safety audits for all types of buildings and industries, including hotels, hospitals, homes, schools, manufacturing plants, chemical plants, power plants, FMCG companies, foundries, mines, etc.
The occurrence of fire has the potential to cause serious damage to life and property. A fire safety audit is the most effective tool to assess the fire safety standards of your facility. It helps owners identify areas for improvement and develop action plans, in addition to preparing for emergencies and conducting test drills.
Safeworld regularly conducts fire safety audits for high-rise buildings, hotels, banks, small, medium, and large-scale industries, etc. Our team conducts fire safety audits based on various IS standards such as Standard for Automatic Fire Detection and Alarm System, Code of Practice for Selection, Installation and Maintenance of Emergency Fire Extinguishers, National Building Code, 2005, Code of Practice for Fire Safety of Buildings, and all other relevant safety standards to identify all the hazards that need to be corrected and prevented.
Main Focus:
- Identify and control ignition sources in areas where flammable chemicals are stored/processed/transferred.
- Evaluate the chemical compatibility of storage areas and recommend appropriate measures to reduce fire damage.
- Check electrical hazards that may cause a fire.
- Evaluate fire detection measures taken and recommend appropriate improvements.
- Verify various active (fire hydrants, sprinklers, portable fire extinguishers) and passive fire protection measures requirements for storage and handling of chemicals and recommend improvements where needed.
- Verify fire alarm systems and emergency fire protection systems in plants
- Review contractor safety awareness (chemical spills, fire protection, emergency communications, knowledge of plant hazards, and safety regulations) and recommend appropriate improvements to improve contractor safety
- Evaluate staff safety awareness and safety training requirements (identification and effectiveness of training) to understand hazards present.
- To arrange your fire safety audit, please email info@ifeindia.org
We conduct fire safety inspections for any type of building structures (factories, hospitals, schools/colleges, commercial buildings, residential areas, etc.) and we have qualified and experienced fire safety professionals. With an extensive network of professionals/inspectors, we can provide timely inspection services anywhere in India.
What is included in a Fire Safety Inspection?
- Conduct a 360-degree assessment of the building.
- Verify the adequacy of fire protection equipment and its maintenance.
- Verify that the building's construction complies with relevant fire safety regulations.
- Check fire incident preparedness (awareness, training, etc.).
Benefits of Fire Safety Audit
- Find out your current compliance with applicable fire safety regulations
- Our inspections are based on the NBC of India
- Upon completion of the fire safety inspection, you will receive a detailed fire safety audit/inspection report. This will help you determine the need for the repair or replacement of fire safety equipment.
Designing Blunders What can go wrong?
Improper Pump Selection or incorrect Pumproom layout
This is observed as a very usual and very expensive mistake done. Wrong pump selection may end up either insufficient flow and pressure at the time of actual fire or non-functional system in long run.
Insufficient Water Storage or Improper Tank Design
This is another common mistake done while designing Fire Sytem. In-sufficient water storage will end up very little time to fight the fire in case of atual fire incedence and wastage of money invested in expensive fire system.
Wrong Pipe Sizing or incorrect provision of valves
Wrong pipe sizing will cause in-sufficient flow and pressure of water at the tip of the nozzle. Each and every outlets are designed to get optimum discharge and rated pressure so none of the area remains unattended.
Insufficient or Single Side Coverage
Wrong pipe sizing will cause in-sufficient flow and pressure of water at the tip of the nozzle. Each and every outlets are desinged to get optimum discharge and rated pressure so none of the area remains unattended.
Incorrect selection of Material
Material selection is a major factor which is being manipluated by many players to show the overall cost of project low. This can be very expensive in long run.
Incorrect methodology of installation
Methodology of installation and workmanship plays a major role in life of any system. Incorrect methodology may invite frequent problems in the system.
Confirming with Prevailing Norms / Standards / Codes / Statutory laws of compliences
Many times it comes as a surprise after the whole erection is done that the system installed is not as per the required standards/norms. This can be very expensive at times as meeting the statutory laws is a time bound affair.
Latest and Best Engineering Practices
Many times one may have to miss the latest and best engineering practices which could be applied without any additional cost many times and can give long term benefits.
Our Prestigious Projects
Gujarat Vidhan Sabha
(Legeislative Assembly)
- Fire Hydrant System
- Sprinkler System
- Fire Detection System
Gujarat High Court
- Fire Hydrant System
- Fire Detection System
- Water Mist System
Tuticorin Port
- Fire Hydrant System on Port as well as on Jetty
- Foam System
Bharat Dimond Bourse
- Fire Hydrant System
- Sprinker System
- Fire Detection System
Adani Wilmar Ltd (Mundra & Kadi Plant)
- Fire Hydrant System
- Sprinker System
- Spray System
Gujarat Industrial Power Corporation Ltd Vadodara
- Fire Hydrant System
Central Electronics Engineering Resarch Institute, Pilani
- Fire Hydrant System
- Fire Detection System
Unimark Remedies, Ahmedabad & Vapi
- Fire Hydrant System
- Sprinkelr System
- Fire Detection System
RSWM (Rajasthan Spinning & Weaving Mills Ltd) - LNJ Group, Kharigram (Gulabpura)
- Fire Hydrant System
- Sprinkelr System
- Fire Detection System
And many more....
Types of Service Provided
Designing Fire System
We can provide Design Engineering Consultancy Services to design any Fire System from scratch OR Design Adequacy Check for any Industrial, Commercial or Residential establishment as per...
- NFPA (National Fire Protection Association)
- FM Global
- TAC
- NBC (National Building Code - India)
- Any other Local Fire Authority Norms
Presentable Drafting or Designing Fire System under Guidance
We provide drafting services for fire systems also wherein designing is already done on paper fully/partially and the presentable design would be provided in softcopy in desirable software. Here, we provide a draftsman who has fair know-how about the fire systems and who can work on quick instructions.
Hydraulic Calculations for Fire System
H
ydraulic calculations
are used to determine the flow of liquids through a medium (usually a piping network) to ensure that
fires
can be adequately controlled
.